RAID 計算機:我需要多少容量? | Seagate 台灣
文章推薦指數: 80 %
JBODRAID 0RAID 1RAID 5RAID 6RAID 10RAID 50RAID 60. JBOD. 本解決方案會使用至少兩台硬碟機組成儲存集區。
JBOD 儲存集區不具備資料備援能力。
RAIDCapacityCalculatorConfigureyouridealsetupandcalculatehowmuchcapacityandredundancyyouneedforstorage.
Required Pleaseselectdrivesontheleft Reset SelectRAIDType ❓ RAIDTYPE JBOD Thesolutioncombinesatleasttwodrivestocreateastoragepool.JBODstoragepoolsdonotofferdataredundancy.TheavailablecapacityofaJBODstoragepoolequalsthetotalcapacityofalldrivesincludedinthestoragepool.JBODsupportscombiningdrivesofdifferentsizes. RAID0 RAID0combinestwoormoredrivestoincreaseperformanceandcapacity,butprovidesnofaulttolerance.Asingledrivefailurewillresultinthelossofalldataonthearray.RAID0isusefulfornon-criticalsystemswhereahighprice/performancebalanceisrequired. RAID1 RAID1ismostoftenimplementedwithtwodrives.Dataonthedrivesismirrored,providingfaulttoleranceincaseofdrivefailure.Readperformanceisincreasedwhilewriteperformancewillbesimilartoasingledrive.Asingledrivefailurecanbesustainedwithoutdataloss.RAID1isoftenusedwhenfaulttoleranceiskey,whilespaceandperformancearenotcriticalrequirements. RAID5 RAID5providesfaulttoleranceandincreasedreadperformance.Atleastthreedrivesarerequired.RAID5cansustainthelossofasingledrive.Intheeventofadrivefailure,datafromthefaileddriveisreconstructedfromparitystripedacrosstheremainingdrives.Asaresult,bothreadandwriteperformanceareseverelyaffectedwhileaRAID5arrayisinadegradedstate.RAID5isidealwhenspaceandcostaremoreimportantthanperformance. RAID6 RAID6issimilartoRAID5,exceptitprovidesanotherlayerofstripingandcansustaintwodrivefailure.Aminimumoffourdrivesisrequired.TheperformanceofRAID6islowerthanthatofRAID5duetothisadditionalfaulttolerance.RAID6becomesattractivewhenspaceandcostareimportantandsustainingmultipledrivefailuresisrequired. RAID10 RAID10combinesthebenefitsofRAID1andRAID0.Readandwriteperformanceisincreased,butonlyhalfofthetotalspaceisavailablefordatastorage.Fourormoredrivesarerequiredmakingthecostrelativelyhigh,buttheperformanceisgreatwhileprovidingfaulttoleranceatthesametime.Infact,aRAID10cansustainmultipledrivefailures—providedthefailuresarenotwithinthesamesubgroup.RAID10isidealforapplicationswithahighinput/outputdemandsuchasdatabaseservers. RAID50 RAID50,alsoknownasRAID5+0,mergesdistributedparity(RAID5)withstriping(RAID0)andrequiresaminimumofsixdrives.ThebenefitsofthisRAIDlevelarebetterwriteperformance,betterdataprotection,andfasterrebuildsthanRAID5.PerformancedoesnotdegradeasmuchasinaRAID5arraybecauseasinglefailureonlyaffectsonearray.UptofourdrivefailurescanbeovercomeifeachfaileddriveoccursinadifferentRAID5array. RAID60 RAID60(orRAID6+0)isahybridthatoffersthedistributeddoubleparityofRAID6withthestraightblock-levelstripingofRAID0.AsaRAID0arraystripedacrossRAID6elements,RAID60requireseightdrivesatminimum.RAID60(6+0)isamultileveldiskset,composedofRAID6setsaggregatedatahigherlevelintoaRAID0array.ARAIDsetoffersredundancyandcanwithstandthelossofuptotwodisksineachparityset.RAID60arraysaremorereliablethanRAID50arraysthankstotheextraparitydiskinRAID60.Butwhenmorethantwodisksinasingleparitysetarelost,theRAID0setbreaks,anddatarecoveryisneeded. SelectDrives HDD SSD Results Pleaseaddatleastdrivesforcapacitycalculator. Capacity Protection Unused HardDrive LearnMore SSD LearnMore *Whenreferringtodrivecapacity,onegigabyte,orGB,equalsonebillionbytes;andoneterabyte,orTB,equalsonetrillionbytes.Yourcomputer’soperatingsystemmayuseadifferentstandardofmeasurementandreportalowercapacity.Inaddition,someofthelistedcapacityisusedforformattingandotherfunctions,andthuswillnotbeavailablefordatastorage.Quantitativeusageexamplesforvariousapplicationsareforillustrativepurposes.Actualquantitieswillvarybasedonvariousfactors,includingfilesize,fileformat,features,andapplicationsoftware.Actualdataratesmayvarydependingonoperatingenvironmentandotherfactors.Seagatereservestherighttochange,withoutnotice,productofferingsorspecifications. ©2019SeagateTechnologyLLC.Allrightsreserved.Seagate,SeagateTechnology,theSpirallogoaretrademarksorregisteredtrademarksofSeagateTechnologyLLCoroneofitsaffiliatedcompaniesintheUnitedStatesand/orothercountries.Allothertrademarksorregisteredtrademarksarethepropertyoftheirrespectiveowners.
ASeagateReport RethinkData:PutMoreofYourBusinessDatatoWork
AboutSeagateOurStoryGlobalCitizenshipTrustCentreQualityAssurance
SupportProductSupportSoftwareDownloadsWarranty&ReplacementsContactUs
PressCentreNewsMediaKitsBrandPortal
Investors
PartnersIndirectPartners&ResellersSeagateChampionsSeagateDirect&SuppliersSeagateTechnologyAllianceProgram
JobsLifeatSeagateDiversity,EquityandInclusionUniversityProgrammes
WheretoBuyProductFinder
©2022 SeagateTechnologyLLCLegal&PrivacyVulnerabilityDisclosure
CookiesSettings
LaCieMaxtorLyveLabsSeagateGovernmentSolutionsSiteMap
×
延伸文章資訊
- 1RAID-6的必要性 - iT 邦幫忙
請教各位高手: 我們最近在評估2U Disk Array,目前的廠商技術都可以做到RAID6,但工程師還是建議用RAID-5加上熱備援即可,請問各位有何建議?謝謝.
- 2RAID 6 是什麼?帶你了解其原理與架構(2021年最新)
RAID6 簡單形容,就是容許同時故障2台硬碟還可正常讀寫,但凌威科技寧可提醒使用者勤做資料備份,也不建議追求容許故障2、3、4台硬碟.
- 3RAID 類型
相較於RAID 6,提供更優異的硬碟故障防護與重建速度。儲存容量高於RAID 10。 如果所有硬碟皆是SSD,其隨機存取效能優於RAID 6。 建議 ...
- 4RAID 6 概念 - IBM
RAID 6 保護可保護資料不會因硬碟機故障或磁碟損壞而遺失。RAID 6 保護最多可保護兩個硬碟機故障。
- 5RAID 計算機:我需要多少容量? | Seagate 台灣
JBODRAID 0RAID 1RAID 5RAID 6RAID 10RAID 50RAID 60. JBOD. 本解決方案會使用至少兩台硬碟機組成儲存集區。JBOD 儲存集區不具備資料備援能力。